In this study is to explain how the electromagnetic interference occur, its environmental hazards and protective method from this hazards. The hazards of electromagnetic interference on people was investigated. Related standards about Electromagnetic Compatibility and Electromagnetic Interference was researched. And also results were presented. More over information about MXF-484 V/UHF airborne radio used for application was given. Environmental effects of electromagnetic field occured by the varying frequency values on the MXF-484 V/UHF airborne radio of utility and attack helicopters were measured. Results of tests were compared according to MIL-STD-464 standard.
Keywords: EMI, EMC, HERF, HERP, HERO.Bu çalışmada, öncelikle elektromanyetik girişimin, nasıl ve neden oluştuğu, çevresel etkileri ve bu etkilerden korunma yöntemleri açıklanmıştır. Elektromanyetik ışımanın zararlı etkileri personel üzerinde incelenmiştir. Bu konuda mevcut standartların neler olduğu araştırılmış, araştırma sonuçları sunulmuştur. Ayrıca uygulama için kullanılan MXF-484 V/UHF hava platform telsizi hakkında bilgi verilmiştir. Genel amaçlı ve taarruz helikopterlerinin hava platform telsizinde değişen frekans değerlerinden kaynaklanan çevresel elektromanyetik alan etkileri ölçülmüştür. Ölçülen elektromanyetik uyumluluk test sonuçları MIL-STD-464 standardı ile karşılaştırılmıştır.
Anahtar Kelimeler: EMI, EMC, HERP, HERF, HERO.